Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 436
Filtrar
1.
Clin Transplant ; 38(3): e15251, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38504576

RESUMO

BACKGROUND: Belatacept (BTC), a fusion protein, selectively inhibits T-cell co-stimulation by binding to the CD80 and CD86 receptors on antigen-presenting cells (APCs) and has been used as immunosuppression in adult renal transplant recipients. However, data regarding its use in heart transplant (HT) recipients are limited. This retrospective cohort study aimed to delineate BTC's application in HT, focusing on efficacy, safety, and associated complications at a high-volume HT center. METHODS: A retrospective cohort study was conducted of patients who underwent HT between January 2017 and December 2021 and subsequently received BTC as part of their immunosuppressive regimen. Twenty-one HT recipients were identified. Baseline characteristics, history of rejection, and indication for BTC use were collected. Outcomes included renal function, graft function, allograft rejection and mortality. Follow-up data were collected through December 2023. RESULTS: Among 776 patients monitored from January 2017 to December 2021 21 (2.7%) received BTC treatment. Average age at transplantation was 53 years (± 12 years), and 38% were women. BTC administration began, on average, 689 [483, 1830] days post-HT. The primary indications for BTC were elevated pre-formed donor-specific antibodies in highly sensitized patients (66.6%) and renal sparing (23.8%), in conjunction with reduced calcineurin inhibitor dosage. Only one (4.8%) patient encountered rejection within a year of starting BTC. Graft function by echocardiography remained stable at 6 and 12 months posttreatment. An improvement was observed in serum creatinine levels (76.2% of patients), decreasing from a median of 1.58 to 1.45 (IQR [1.0-2.1] to [1.1-1.9]) over 12 months (p = .054). eGFR improved at 3 and 6 months compared with 3 months pre- BTC levels; however, this was not statistically significant (p = .24). Treatment discontinuation occurred in seven patients (33.3%) of whom four (19%) were switched back to full dose CNI. Infections occurred in 11 patients (52.4%), leading to BTC discontinuation in 4 patients (19%). CONCLUSION: In this cohort, BTC therapy was used as alternative immunosuppression for management of highly sensitized patients or for renal sparing. BTC therapy when combined with CNI dose reduction resulted in stabilization in renal function as measured through renal surrogate markers, which did not, however, reach statistical significance. Patients on BTC maintained a low rejection rate and preserved graft function. Infections were common during BTC therapy and were associated with medication pause/discontinuation in 19% of patients. Further randomized studies are needed to assess the efficacy and safety of BTC in HT recipients.


Assuntos
Transplante de Coração , Transplante de Rim , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Abatacepte , Estudos Retrospectivos , Transplante de Rim/efeitos adversos , Imunossupressores , Inibidores de Calcineurina/uso terapêutico , Linfócitos T , Rejeição de Enxerto/tratamento farmacológico , Rejeição de Enxerto/etiologia , Transplantados , Sobrevivência de Enxerto
2.
Circ Heart Fail ; 17(3): e011115, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38456308

RESUMO

BACKGROUND: Although much attention has been paid to admission and transfer patterns for cardiogenic shock, contemporary data are lacking on decompensated heart failure (HF) admissions and transfers and the impact of advanced therapy centers (ATCs) on outcomes. METHODS: HF hospitalizations were obtained from the Nationwide Readmissions Database 2016 to 2019. Centers performing at least 1 heart transplant or left ventricular assist device were classified as ATCs. Patient characteristics, outcomes, and procedural volume were compared among 3 cohorts: admissions to non-ATCs, admissions to ATCs, and transfers to ATCs. A secondary analysis evaluated outcomes for severe HF hospitalizations (cardiogenic shock, cardiac arrest, and mechanical ventilation). Multivariable logistic regression was performed to adjust for the presence of HF decompensations and significant clinical variables during univariate analysis. RESULTS: A total of 2 331 690 hospitalizations (81.2%) were admissions to non-ATCs (94.5% of centers), 525 037 (18.3%) were admissions to ATCs (5.5% of centers), and 15 541 (0.5%) were transferred to ATCs. Patients treated at ATCs (especially those transferred) had higher rates of HF decompensations, procedural frequency, lengths of stay, and costs. Unadjusted mortality was 2.6% at non-ATCs and was higher at ATCs, both for directly admitted (2.9%, P<0.001) and transferred (11.2%, P<0.001) patients. However, multivariable-adjusted mortality was significantly lower at ATCs, both for directly admitted (odds ratio, 0.82 [95% CI, 0.78-0.87]; P<0.001) and transferred (odds ratio, 0.66 [95% CI, 0.57-0.78]; P<0.001) patients. For severe HF admissions, unadjusted mortality was 37.2% at non-ATCs and was lower at ATCs, both for directly admitted (25.3%, P<0.001) and transferred (25.2%, P<0.001) patients, with similarly lower multivariable-adjusted mortality. CONCLUSIONS: Patients with HF treated at ATCs were sicker but associated with higher procedural volume and lower adjusted mortality.


Assuntos
Parada Cardíaca , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Choque Cardiogênico/complicações , Hospitalização , Mortalidade Hospitalar
3.
Artigo em Inglês | MEDLINE | ID: mdl-38367698

RESUMO

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

4.
ASAIO J ; 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38373176

RESUMO

In patients supported by the HeartMate 3 left ventricular assist device (HM3 LVAD), pump speed adjustments may improve hemodynamics. We investigated the hemodynamic implications of speed adjustments in HM3 recipients undergoing hemodynamic ramp tests. Clinically stable HM3 recipients who underwent routine invasive hemodynamic ramp tests between 2015 and 2022 at our center were included. Filling pressure optimization, defined as central venous pressure (CVP) <12 mm Hg and pulmonary capillary wedge pressure (PCWP) <18 mm Hg, was assessed at baseline and final pump speeds. Patients with optimized pressures were compared to nonoptimized patients. Overall 60 HM3 recipients with a median age of 62 years (56, 71) and time from LVAD implantation of 187 days (124, 476) were included. Optimized filling pressures were found in 35 patients (58%) at baseline speed. Speed was adjusted in 84% of the nonoptimized patients. Consequently, 39 patients (65%) had optimized pressures at final speed. There were no significant differences in hemodynamic findings between baseline and final speeds (p > 0.05 for all). Six and 12 month readmission-free rates were higher in optimized compared with nonoptimized patients (p = 0.03 for both), predominantly due to lower cardiac readmission-free rates (p = 0.052). In stable outpatients supported with HM3 who underwent routine ramp tests, optimized hemodynamics were achieved in only 2 of 3 of the patients. Patients with optimized pressures had lower all-cause readmission rates, primarily driven by fewer cardiac-related hospitalizations.

5.
J Am Heart Assoc ; 13(3): e032607, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38240236

RESUMO

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly used for patients with cardiogenic shock. Although Impella or intra-aortic balloon pump (IABP) is frequently used for left ventricular unloading (LVU) during VA-ECMO treatment, there are limited data on comparative outcomes. We compared outcomes of Impella and IABP for LVU during VA-ECMO. METHODS AND RESULTS: Using the Nationwide Readmissions Database between 2016 and 2020, we analyzed outcomes in 3 groups of patients with cardiogenic shock requiring VA-ECMO based on LVU strategies: extracorporeal membrane oxygenation (ECMO) only, ECMO with IABP, and ECMO with Impella. Of 15 980 patients on VA-ECMO, IABP and Impella were used in 19.4% and 16.4%, respectively. The proportion of patients receiving Impella significantly increased from 2016 to 2020 (6.5% versus 25.8%; P-trend<0.001). In-hospital mortality was higher with ECMO with Impella (54.8%) compared with ECMO only (50.4%) and ECMO with IABP (48.4%). After adjustment, ECMO with IABP versus ECMO only was associated with lower in-hospital mortality (adjusted odds ratio [aOR], 0.83; P=0.02). ECMO with Impella versus ECMO only had similar in-hospital mortality (aOR, 1.09; P=0.695) but was associated with more bleeding (aOR, 1.21; P=0.007) and more acute kidney injury requiring hemodialysis (aOR, 1.42; P<0.001). ECMO with Impella versus ECMO with IABP was associated with greater risk of acute kidney injury requiring hemodialysis (aOR, 1.49; P=0.002), higher in-hospital mortality (aOR, 1.32; P=0.001), and higher 40-day mortality (hazard ratio, 1.25; P<0.001). CONCLUSIONS: In patients with cardiogenic shock on VA-ECMO, LVU with Impella, particularly with 2.5/CP, was not associated with improved survival at 40 days but was associated with increased adverse events compared with IABP. More data are needed to assess Impella platform-specific comparative outcomes of LVU.


Assuntos
Injúria Renal Aguda , Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Humanos , Choque Cardiogênico , Balão Intra-Aórtico/efeitos adversos , Terapia Combinada , Injúria Renal Aguda/etiologia , Resultado do Tratamento
6.
J Heart Lung Transplant ; 43(4): 642-651, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38070663

RESUMO

BACKGROUND: The physiological response of the right ventricle (RV) following left ventricular assist device (LVAD) implantation is difficult to predict. We aimed to investigate RV geometric and functional changes after LVAD insertion and their effects on clinical outcomes. METHODS: We retrospectively reviewed 188 patients who underwent HeartMate 3 implantation at our center between November 2014 and September 2021. The RV end-diastolic diameter (RVEDD) and RV end-diastolic area (RVEDA) were measured on preoperative and predischarge transthoracic echocardiography. The nonadapted group included patients with increased RVEDD and RVEDA at discharge. The composite outcome was defined as death or readmission due to worsening right heart failure. RESULTS: There were 82 patients (44%) who had a nonadapted and 106 patients (56%) who had an adapted RV. Preoperatively, the nonadapted group had smaller RVEDD (46 vs 49 mm, p < 0.001) and RVEDA (27 vs 31 cm2, p < 0.001). At discharge, the nonadapted group had larger RVEDD (51 vs 43 mm, p < 0.001) and RVEDA (33 vs 27 cm2, p < 0.001). Kaplan-Meier analysis demonstrated worse 3-year survival (77% vs 91%, p = 0.006) and freedom from composite outcome (58% vs 85%, p < 0.001) in the nonadapted group. A multivariable Cox proportional hazards model showed that nonadaption (hazard ratio [HR] 3.09, 95% confidence interval [CI] 1.29-7.40, p = 0.01) and age (HR 3.73, 95% CI 1.42-9.77, p = 0.007) were independent predictors of composite outcome. CONCLUSIONS: Acute RV dimensional changes after LVAD insertion may represent intrinsic RV function and may be a useful prognostic marker.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Humanos , Ventrículos do Coração/diagnóstico por imagem , Estudos Retrospectivos , Ecocardiografia , Função Ventricular Direita
8.
J Card Fail ; 30(1): 95-99, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37625582

RESUMO

BACKGROUND: Aortic regurgitation (AR) is a common complication following left ventricular assist device (LVAD) implantation. We evaluated the hemodynamic implications of AR in patients with HeartMate 3 (HM3) LVAD at baseline and in response to speed changes. METHODS AND RESULTS: Clinically stable outpatients supported by HM3 who underwent a routine hemodynamic ramp test were retrospectively enrolled in this analysis. Patients were stratified based on the presence of at least mild AR at baseline speed. Hemodynamic and echocardiographic parameters were compared between the AR and non-AR groups. Sixty-two patients were identified. At the baseline LVAD speed, 29 patients (47%) had AR, while 33 patients (53%) did not. Patients with AR were older and supported on HM3 for a longer duration. At baseline speed, all hemodynamic parameters were similar between the groups including central venous pressure, pulmonary capillary wedge pressure, pulmonary arterial pressures, cardiac output and index, and pulmonary artery pulsatility index (p > 0.05 for all). During the subacute assessment, AR worsened in some, but not all, patients, with increases in LVAD speed. There were no significant differences in 1-year mortality or hospitalization rates between the groups, however, at 1-year, ≥ moderate AR and right ventricular failure (RVF) were detected in higher rates among the AR group compared to the non-AR group (45% vs. 0%; p < 0.01, and 75% vs. 36.8%; p = 0.02, respectively). CONCLUSIONS: In a cohort of stable outpatients supported with HM3 who underwent a routine hemodynamic ramp test, the presence of mild or greater AR did not impact the ability of HM3 LVADs to effectively unload the left ventricle during early subacute assessment. Although the presence of AR did not affect mortality and hospitalization rates, it resulted in higher rates of late hemodynamic-related events in the form of progressive AR and RVF.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estudos Retrospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Hemodinâmica/fisiologia
9.
Artigo em Inglês | MEDLINE | ID: mdl-38154500

RESUMO

OBJECTIVE: To compare 3-year survival and readmissions of patients who received the HeartMate 3 (HM3) left ventricular assist device (LVAD) or underwent orthotopic heart transplantation (OHT) as primary treatment for advanced heart failure. METHODS: We retrospectively analyzed 381 adult patients who received an HM3 LVAD or were listed for OHT between January 2014 and March 2021 at our center. To minimize crossover bias, OHT recipients with a prior LVAD were excluded, and HM3 patients were censored at the time of transplant. Cohorts were propensity score-matched to reduce confounding variables. The primary outcome was 3-year survival, and the secondary outcome was mean cumulative all-cause unplanned readmission. RESULTS: The study population comprised 185 HM3 patients (49%) and 196 OHT patients (51%), with 104 propensity score-matched patients in each group. After propensity score matching, there was no statistical difference in 3-year survival (83.7% for HM3 vs 87.0% for OHT; P = .91; relative risk [RR], 1.00; 95% confidence interval [CI], 0.45-2.20). In the unmatched cohorts, patients age 18 to 49 years had comparable survival with HM3 and OHT (96.9% vs 95.9%; N = 91; P = 1.00; RR, 0.92; 95% CI, 0.09-9.78). Patients age 50+ years had slightly inferior survival with HM3 (75.0% vs 83.9%; N = 290; P = .60; RR, 1.51; 95% CI, 0.85-2.68). The mean number of readmissions at 3 years was higher in the HM3 group (3.89 vs 2.05; P < .001). CONCLUSIONS: This exploratory analysis suggests that for similar patients, HM3 may provide comparable 3-year survival to OHT as a primary treatment for heart failure but may result in more readmissions.

10.
ASAIO J ; 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37934714

RESUMO

This review discusses the challenges and outcomes associated with pregnancy during left ventricular assist device (LVAD) support. Women account for a third of the heart failure population in the United States. Left ventricular assist devices have emerged as a safe and effective treatment option for patients with advanced heart failure. Pregnancy during LVAD support can occur, and it presents significant risks to both mother and fetus, including hemodynamic stress, thrombotic events, medication-associated teratogenicity, and uterine impingement. This literature review identified 10 cases of confirmed pregnancy during LVAD support, of which eight resulted in successful births. Maternal and fetal mortality occurred in one case, and there was a spontaneous abortion in one case. The review highlights the importance of a multidisciplinary approach, promotion of shared decision-making, thoughtful anticoagulation, adjustment of LVAD speed, and medication optimization to maintain hemodynamic support during pregnancy. Hemodynamic changes during pregnancy include increased cardiac output, heart rate, and plasma volume, as well as decreased systemic vascular resistance, which can impact LVAD support. Despite reduced pulsatility in LVAD-supported patients, ovulation and reproductive capacity might be preserved, and viable pregnancies may be achieved with appropriate management. The review provides insights into the risks and considerations for a viable pregnancy during LVAD support, including the need for ongoing research to inform joined decision-making.

11.
JTCVS Open ; 15: 262-289, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37808044

RESUMO

Objective: This study assessed characteristics and outcomes of younger (18-65) versus older (>65) recipients of simultaneous heart-kidney (SHK) transplantation with varying functional dependence. Methods: This study retrospectively analyzed 1398 patients from the United Network for Organ Sharing database who received SHK between 2010 and 2021. Patients who were <18 year old, underwent transplant of additional organs simultaneously, or had previous heart transplant were excluded. The primary end point was all-cause mortality, and secondary end points included adverse events and cause of death. Outcomes were also evaluated by propensity score-matched comparison. Results: The number of annual SHK transplantation in the United States has significantly increased among both age groups over the past 2 decades (P < .0001). After propensity score matching of recipients aged 18 to 65 years (n = 1162) versus age >65 years (n = 236), baseline characteristics were similar and well-balanced between the 2 cohorts. Between matched cohorts, older recipients did not have increased posttransplant mortality compared with younger recipients (90-day survival, P = .85; 7-year survival, P = .61). Multivariable Cox regression analysis found that age (hazard ratio [HR], 1.039 [0.975-1.106], P = .2415) and pretransplant functional status with interaction term for age (some assistance, HR, 0.965 [0.902-1.033], P = .3079; total assistance, HR, 0.976 [0.914-1.041], P = .4610) were not significant risk factors for 7-year post-SHK transplantation mortality. Conclusions: Older and more functionally dependent recipients in this study did not have increased post-SHK transplantation mortality. These findings have important implications for organ allocation among elderly patients, as they support the need for thorough assessment of SHK candidates in terms of comorbidities, rather than exclusion solely based on age and functional dependence.

12.
Artigo em Inglês | MEDLINE | ID: mdl-37824209

RESUMO

OBJECTIVES: Lateral thoracotomy (LT) approach may preserve the right ventricular (RV) function after left ventricular assist device (LVAD) implantation. This study evaluated the short- and long-term RV function using echocardiography after LVAD implantation via LT or median sternotomy (sternotomy). METHODS: The patients who underwent HeartMate 3 implantation were retrospectively reviewed. The RV function was assessed before and 1 month and 1 year after LVAD implantation. The primary and secondary outcomes were all-cause mortality and a composite of death or readmission due to RV failure, respectively. RESULTS: Of the 195 patients, 55 (28%) underwent LT and 140 (72%) underwent sternotomy. There were no significant differences in the preoperative RV geometry or function. One month after the LVAD implantation, the LT group had a smaller RV end-diastolic dimension [42 (29-48) vs 47 (42-52) mm; P = 0.003] and RV end-diastolic area [25 (21-28) vs 29 (24-36) cm2; P < 0.001] and a greater RV fractional area change [30 (25-34)% vs 28 (23-31)%; P = 0.04] and peak systolic tissue velocity [8 (7-9) vs 7 (6-8) cm/s; P = 0.01]. Twenty-four patients died and 46 met the composite end point. Kaplan-Meier curve analysis did not reveal significant differences between LT and sternotomy in the 2-year survival (93% vs 83%; log-rank test, P = 0.28) and adverse event rate (76% vs 71%; log-rank test, P = 0.65). CONCLUSIONS: LT approach yielded a better-preserved RV function at 1 month; however, there were no significant differences in the 2-year survival and adverse event rates.

13.
Artigo em Inglês | MEDLINE | ID: mdl-37739242

RESUMO

BACKGROUND: Aortic root thrombosis(ART) is a complication of continuous-flow left ventricular assist device therapy. However, the incidence and related complications of ART in HeartMate 3 (HM3) patients remain unknown. METHODS: Patients who underwent HM3 implantation from November 2014 to August 2020 at a quaternary academic medical center were included. Demographics and outcomes were abstracted from the medical record. Echocardiograms and contrast-enhanced computed tomography studies were reviewed to identify patients who developed ART and/or moderate or greater aortic insufficiency (AI) on HM3 support. RESULTS: The study cohort included 197 HM3 patients with a median postimplant follow-up of 17.5 months. Nineteen patients (9.6%) developed ART during HM3 support, and 15 patients (7.6%) developed moderate or greater AI. Baseline age, gender, race, implantation strategy, and INTERMACS classification were similar between the ART and no-ART groups. ART was associated with an increased risk of death, stroke, or aortic valve (AV) intervention (subhazard ratio [SHR] 3.60 [95% confidence interval (CI) 1.71-7.56]; p = 0.001) and moderate or greater AI (SHR 11.1 [CI 3.60-34.1]; p < 0.001) but was not associated with a statistically significantly increased risk of death or stroke on HM3 support (2.12 [0.86-5.22]; p = 0.10). Of the 19 patients with ART, 6 (31.6%) developed moderate or greater AI, necessitating more frequent AV interventions (ART: 5 AV interventions [3 surgical repairs, 1 surgical replacement, 1 transcatheter replacement; 26.3%]; no-ART: 0). CONCLUSIONS: Nearly 10% of HM3 patients developed ART during device support. ART was associated with increased risk of a composite end-point of death, stroke, or AV intervention as well as moderate or greater AI.

14.
J Am Coll Cardiol ; 82(9): 771-781, 2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37612008

RESUMO

BACKGROUND: In advanced heart failure patients implanted with a fully magnetically levitated HeartMate 3 (HM3, Abbott) left ventricular assist device (LVAD), it is unknown how preimplant factors and postimplant index hospitalization events influence 5-year mortality in those able to be discharged. OBJECTIVES: The goal was to identify risk predictors of mortality through 5 years among HM3 LVAD recipients conditional on discharge from index hospitalization in the MOMENTUM 3 pivotal trial. METHODS: This analysis evaluated 485 of 515 (94%) patients discharged after implantation of the HM3 LVAD. Preimplant (baseline), implant surgery, and index hospitalization characteristics were analyzed individually, and as multivariable predictors for mortality risk through 5 years. RESULTS: Cumulative 5-year mortality in the cohort (median age: 62 years, 80% male, 65% White, 61% destination therapy due to transplant ineligibility) was 38%. Two preimplant characteristics (elevated blood urea nitrogen and prior coronary artery bypass graft or valve procedure) and 3 postimplant characteristics (hemocompatibility-related adverse events, ventricular arrhythmias, and estimated glomerular filtration rate <60 mL/min/1.73 m2 at discharge) were predictors of 5-year mortality. In 171 of 485 patients (35.3%) without any risk predictors, 5-year mortality was reduced to 22.6% (95% CI: 15.4%-32.7%). Even among those with 1 or more predictors, mortality was <50% at 5 years (45.7% [95% CI: 39.0%-52.8%]). CONCLUSIONS: Long-term survival in successfully discharged HM3 LVAD recipients is largely influenced by clinical events experienced during the index surgical hospitalization in tandem with baseline factors, with mortality of <50% at 5 years. In patients without identified predictors of risk, long-term 5-year mortality is low and rivals that achieved with heart transplantation, even though most were implanted with destination therapy intent. (MOMENTUM 3 IDE Clinical Study Protocol, NCT02224755; MOMENTUM 3 Pivotal Cohort Extended Follow-up PAS, NCT03982979).


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ponte de Artéria Coronária , Insuficiência Cardíaca/terapia , Hospitalização , Alta do Paciente
15.
Eur J Cardiothorac Surg ; 64(2)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37589647

RESUMO

OBJECTIVES: We investigated the association between indexed left ventricular diastolic dimension and clinical outcomes after HeartMate 3 implantation. METHODS: We retrospectively reviewed patients implanted with the HeartMate 3 at our centre between November 2014 and September 2021. Left ventricular diastolic dimension was assessed via preoperative transthoracic echocardiography and left ventricular diastolic dimension index was calculated as left ventricular diastolic dimension/body surface area. The primary outcome was a composite of death or readmission due to right heart failure or stroke. The cut-off left ventricular diastolic dimension index value most closely associated with outcomes was determined by receiver-operating characteristic curve and restricted cubic spline analyses. RESULTS: Left ventricular diastolic dimension index measurements were available for 252 of 253 (99.6%) patients. Using a left ventricular diastolic dimension index cut-off value of 33.5 mm/m2, the cohort was divided: left ventricular diastolic dimension index ≤ (n = 131) or > (n = 121) 33.5 mm/m2. While there were no significant differences in age, INTERMACS level and preoperative haemodynamics between groups, patients with smaller left ventricular diastolic dimension index were more likely to have a larger body surface area (2.1 vs 1.9 m2, P < 0.001), ischaemic cardiomyopathy [64 (49%) vs 40 (33%), P = 0.01] and smaller left atrium volume index [40.5 (32.3-54.0) ml/m2 vs 54.0 (43.0-66.8) ml/m2, P < 0.001]. Smaller left ventricular diastolic dimension index patients had significantly worse survival (74% vs 88%, log-rank P = 0.009) and freedom from adverse events (55% vs 73%, log-rank P = 0.005) at 3-year follow-up. Smaller left ventricular diastolic dimension index was independently associated with the composite outcome (Hazard ratio 2.24, P = 0.002). CONCLUSIONS: Smaller preoperative left ventricular diastolic dimension index is associated with worse outcomes in patients undergoing HeartMate 3 implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estudos Retrospectivos , Ventrículos do Coração/diagnóstico por imagem , Implantação de Prótese , Ecocardiografia , Coração Auxiliar/efeitos adversos , Resultado do Tratamento
17.
J Clin Med ; 12(10)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37240461

RESUMO

Primary cardiac schwannoma (PCS) is a neurogenic tumor that arises from Schwann cells. Malignant schwannoma (MSh) is an aggressive cancer comprising 2% of all sarcomas. Information on the proper management of these tumors is limited. Four databases were searched for case reports/series of PCS. The primary outcome was overall survival (OS). Secondary outcomes included therapeutic strategies and the corresponding outcomes. Among 439 potentially eligible studies, 53 met the inclusion criteria. The patients included had 43.72 ± 17.76 years and 28.3% were males. Over 50% of patients had MSh, with 9.4% also demonstrating metastases. Schwannoma commonly occurs in the atria (66.0%). Left-sided PCS were more common than right-sided ones. Surgery was performed in almost 90% of the cases; chemotherapy and radiotherapy were used in 16.9% and 15.1% of cases, respectively. Compared to benign cases, MSh occurs at a younger age and is commonly located on the left side. OS of the entire cohort at 1 and 3 years were 60.7%, and 54.0%, respectively. Females and males OS were similar up to 2 years follow-up. Surgery was associated with higher OS (p < 0.01). Surgery is the primary treatment option for both benign and malignant cases and was the only factor associated with a relative improvement in survival.

18.
J Heart Lung Transplant ; 42(9): 1223-1232, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37098374

RESUMO

BACKGROUND: Reduced arterial pulsatility in continuous-flow left ventricular assist devices (CF-LVAD) patients has been implicated in clinical complications. Consequently, recent improvements in clinical outcomes have been attributed to the "artificial pulse" technology inherent to the HeartMate3 (HM3) LVAD. However, the effect of the "artificial pulse" on arterial flow, transmission of pulsatility into the microcirculation and its association with LVAD pump parameters is not known. METHODS: The local flow oscillation (pulsatility index, PI) of common carotid arteries (CCAs), middle cerebral arteries (MCAs) and central retinal arteries (CRAs-representing the microcirculation) were quantified by 2D-aligned, angle-corrected Doppler ultrasound in 148 participants: healthy controls, n = 32; heart failure (HF), n = 43; HeartMate II (HMII), n = 32; HM3, n = 41. RESULTS: In HM3 patients, 2D-Doppler PI in beats with "artificial pulse" and beats with "continuous-flow" was similar to that of HMII patients across the macro- and microcirculation. Additionally, peak systolic velocity did not differ between HM3 and HMII patients. Transmission of PI into the microcirculation was higher in both HM3 (during the beats with "artificial pulse") and in HMII patients compared with HF patients. LVAD pump speed was inversely associated with microvascular PI in HMII and HM3 (HMII, r2 = 0.51, p < 0.0001; HM3 "continuous-flow," r2 = 0.32, p = 0.0009; HM3 "artificial pulse," r2 = 0.23, p = 0.007), while LVAD pump PI was only associated with microcirculatory PI in HMII patients. CONCLUSIONS: The "artificial pulse" of the HM3 is detectable in the macro- and microcirculation but without creating a significant alteration in PI compared with HMII patients. Increased transmission of pulsatility and the association between pump speed and PI in the microcirculation indicate that the future clinical care of HM3 patients may involve individualized pump settings according to the microcirculatory PI in specific end-organs.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Microcirculação , Insuficiência Cardíaca/cirurgia , Frequência Cardíaca , Artéria Cerebral Média
20.
J Heart Lung Transplant ; 42(1): 64-75, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36400676

RESUMO

BACKGROUND: Continuous-flow left ventricular assist devices commonly lead to aortic regurgitation, which results in decreased pump efficiency and worsening heart failure. We hypothesized that non-physiological wall shear stress and oscillatory shear index alter the abundance of structural proteins in aortic valves of left ventricular assist device (LVAD) patients. METHODS: Doppler images of aortic valves of patients undergoing heart transplants were obtained. Eight patients had been supported with LVADs, whereas 10 were not. Aortic valve tissue was collected and protein levels were analyzed using mass spectrometry. Echocardiographic images were analyzed and wall shear stress and oscillatory shear index were calculated. The relationship between normalized levels of individual proteins and in vivo echocardiographic measurements was evaluated. RESULTS: Of the 57 proteins of interest, there was a strong negative correlation between levels of 15 proteins and the wall shear stress (R < -0.500, p ≤ 0.05), and a moderate negative correlation between 16 proteins and wall shear stress (R -0.500 to -0.300, p ≤ 0.05). Gene ontology analysis demonstrated clusters of proteins involved in cellular structure. Proteins negatively correlated with WSS included those with cytoskeletal, actin/myosin, cell-cell junction and extracellular functions. C: In aortic valve tissue, 31 proteins were identified involved in cellular structure and extracellular junctions with a negative correlation between their levels and wall shear stress. These findings suggest an association between the forces acting on the aortic valve (AV) and leaflet protein abundance, and may form a mechanical basis for the increased risk of aortic leaflet degeneration in LVAD patients.


Assuntos
Insuficiência da Valva Aórtica , Transplante de Coração , Coração Auxiliar , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Coração Auxiliar/efeitos adversos , Insuficiência da Valva Aórtica/etiologia , Aorta , Transplante de Coração/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA